首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   104篇
  免费   42篇
  国内免费   11篇
测绘学   2篇
地球物理   4篇
地质学   149篇
自然地理   2篇
  2022年   4篇
  2020年   3篇
  2019年   4篇
  2016年   18篇
  2015年   15篇
  2014年   14篇
  2013年   19篇
  2012年   26篇
  2011年   18篇
  2010年   11篇
  2009年   6篇
  2008年   4篇
  2007年   2篇
  2005年   2篇
  2001年   2篇
  2000年   1篇
  1999年   6篇
  1998年   2篇
排序方式: 共有157条查询结果,搜索用时 280 毫秒
1.
We introduce and propose zircon M257 as a future reference material for the determination of zircon U‐Pb ages by means of secondary ion mass spectrometry. This light brownish, flawless, cut gemstone specimen from Sri Lanka weighed 5.14 g (25.7 carats). Zircon M257 has TIMS‐determined, mean isotopic ratios (2s uncertainties) of 0.09100 ± 0.00003 for 206pb/238U and 0.7392 ± 0.0003 for 207pb/235U. Its 206pb/238U age is 561.3 ± 0.3 Ma (unweighted mean, uncertainty quoted at the 95% confidence level); the U‐Pb system is concordant within uncertainty of decay constants. Zircon M257 contains ~ 840 μg g?1 U (Th/U ~ 0.27). The material exhibits remarkably low heterogeneity, with a virtual absence of any internal textures even in cathodoluminescence images. The uniform, moderate degree of radiation damage (estimated from the expansion of unit‐cell parameters, broadening of Raman spectral parameters and density) corresponds well, within the “Sri Lankan trends”, with actinide concentrations, U‐Pb age, and the calculated alpha fluence of 1.66 × 1018 g?1. This, and a (U+Th)/He age of 419 ± 9 Ma (2s), enables us to exclude any unusual thermal history or heat treatment, which could potentially have affected the retention of radiogenic Pb. The oxygen isotope ratio of this zircon is 13.9%o VSMOW suggesting a metamorphic genesis in a marble or calc‐silicate skarn.  相似文献   
2.
IGN is in charge of the installation and maintenance of the DORIS orbit determination network. More recently, in collaboration with JPL, precise geodetic computations were performed. The goal of this paper is to recall the various historic contributions of IGN to the DORIS system in their international context and then to describe a new estimation technique developed for a multi-satellite mode, making full profit of a better modeling for satellites and ground clocks as well as tropospheric correction parameters. Derived geodetic results demonstrate a precision in the order of 1 cm for station positions. To cite this article: P. Willis et al., C. R. Geoscience 337 (2005).  相似文献   
3.
The double‐spike method with multi‐collector inductively coupled plasma‐mass spectrometry was used to measure the Mo mass fractions and isotopic compositions of a set of geological reference materials including the mineral molybdenite, seawater, coral, as well as igneous and sedimentary rocks. The long‐term reproducibility of the Mo isotopic measurements, based on two‐year analyses of NIST SRM 3134 reference solutions and seawater samples, was ≤ 0.07‰ (two standard deviations, 2s, n = 167) for δ98/95Mo. Accuracy was evaluated by analyses of Atlantic seawater, which yielded a mean δ98/95Mo of 2.03 ± 0.06‰ (2s, n = 30, relative to NIST SRM 3134 = 0‰) and mass fraction of 0.0104 ± 0.0006 μg g?1 (2s, n = 30), which is indistinguishable from seawater samples taken world‐wide and measured in other laboratories. The comprehensive data set presented in this study serves as a reference for quality assurance and interlaboratory comparison of high‐precision Mo mass fractions and isotopic compositions.  相似文献   
4.
Copper speciation in a collection of Japanese geochemical reference materials (JSO‐1, JLk‐1, JSd‐1, ‐2, ‐3 and ‐4, JMs‐1 and JMs‐2) was achieved by sequential extraction and characterised using X‐ray absorption near‐edge structure spectroscopy. In the first step of the extraction, referred to as the acid fraction, between 1% and 20% total Cu within the reference materials was extracted. Such a result is typically accounted for by absorption of Cu onto clay minerals. However, the presence of Cu sulfate (an oxidation product of chalcopyrite) was observed in some of the stream sediments affected by mining activity (JSd‐2 and JSd‐3) instead. Copper was extracted in the reducible fraction (targeting Fe hydroxide and Mn oxide) (2–49% total Cu). Between 2% and 51% Cu was extracted in the oxidised fraction (targeting sulfides and organic matter). X‐ray absorption near‐edge structure spectroscopy clarified that the reducible fraction consisted of Cu bound to Fe hydroxide, whereas the oxidised fraction was a mixture of Cu bound to humic acid (HA) and Cu sulfide. In the oxidisable fraction, chalcopyrite was the predominant species identified in JSd‐2, and Cu bound to HA was the major species identified in JSO‐1 (a soil sample).  相似文献   
5.
The Lamont‐Doherty Earth Observatory radiogenic isotope group has been systematically measuring Sr‐Nd‐Pb‐Hf isotopes of USGS reference material BCR‐2 (Columbia River Basalt 2), as a chemical processing and instrumental quality control monitor for isotopic measurements. BCR‐2 is now a widely used geochemical inter‐laboratory reference material (RM), with its predecessor BCR‐1 no longer available. Recognising that precise and accurate data on RMs is important for ensuring analytical quality and for comparing data between different laboratories, we present a compilation of multiple digestions and analyses made on BCR‐2 during the first author's dissertation research. The best estimates of Sr, Nd and Hf isotope ratios and measurement reproducibilities, after filtering at the 2s level for outliers, were 87Sr/86Sr = 0.705000 ± 11 (2s, 16 ppm, n = 21, sixteen digestions, one outlier), 143Nd/144Nd = 0.512637 ± 13 (2s, 25 ppm, n = 27, thirteen digestions, one outlier) and 176Hf/177Hf = 0.282866 ± 11 (2s, 39 ppm, n = 25, thirteen digestions, no outliers). Mean Nd and Hf values were within error of those reported by Weis et al. (2006, 2007) in their studies of RMs; mean Sr values were just outside the 2s uncertainty range of both laboratories. Moreover, a survey of published Sr‐Nd‐Hf data shows that our results fall within the range of reported values, but with a smaller variability. Our Pb isotope results on acid leached BCR‐2 aliquots (n = 26, twelve digestions, two outliers) were 206Pb/204Pb = 18.8029 ± 10 (2s, 55 ppm), 207Pb/204Pb = 15.6239 ± 8 (2s, 52 ppm), 208Pb/204Pb = 38.8287 ± 25 (2s, 63 ppm). We confirm that unleached BCR‐2 powder is contaminated with Pb, and that sufficient leaching prior to digestion is required to achieve accurate values for the uncontaminated Pb isotopic compositions.  相似文献   
6.
Trace elements from samples of bauxite deposits can provide useful information relevant to the exploration of the ore‐forming process. Sample digestion is a fundamental and critical stage in the process of geochemical analysis, which enables the acquisition of accurate trace element data by ICP‐MS. However, the conventional bomb digestion method with HF/HNO3 results in a significant loss of rare earth elements (REEs) due to the formation of insoluble AlF3 precipitates during the digestion of bauxite samples. In this study, the digestion capability of the following methods was investigated: (a) ‘Mg‐addition’ bomb digestion, (b) NH4HF2 open vessel digestion and (c) NH4F open vessel digestion. ‘Mg‐addition’ bomb digestion can effectively suppress the formation of AlF3 and simultaneously ensure the complete decomposition of resistant minerals in bauxite samples. The addition of MgO to the bauxite samples resulted in (Mg + Ca)/Al ratios ≥ 1. However, adding a large amount of MgO leads to significant blank contamination for some transition elements (V, Cr, Ni and Zn). The NH4HF2 or NH4F open vessel digestion methods can also completely digest resistant minerals in bauxite samples in a short period of time (5 hr). Unlike conventional bomb digestion with HF/HNO3, the white precipitates and the semi‐transparent gels present in the NH4HF2 and NH4F digestion methods could be efficiently dissolved by evaporation with HClO4. Based on these three optimised digestion methods, thirty‐seven trace elements including REEs in ten bauxite reference materials (RMs) were determined by ICP‐MS. The data obtained showed excellent inter‐method reproducibility (agreement within 5% for REEs). The relative standard deviation (% RSD) for most elements was < 6%. The concentrations of trace elements in the ten bauxite RMs showed agreement with the limited certified (Li, V, Cr, Cu, Zn, Ga, Sr, Zr and Pb) and information values (Co, Ba, Ce and Hf) available. New trace element data for the ten RMs are provided, some of which for the first time.  相似文献   
7.
Due to intensive research into selenium isotopes in recent years, the increasing requirement for reliable and comparable measurement results has created a strong demand for selenium isotopic certified reference materials (iCRM) that were previously not available. To address this, eleven selenium iCRMs were developed, including ten synthetic iCRMs (GBW 04447–GBW 04456) and one natural iCRM (GBW 04457). The synthetic iCRMs were prepared with 76Se, 78Se, 80Se and 82Se solutions and a natural selenium solution; the natural iCRM was prepared with highly pure selenium material. The property values of isotope ratios in these iCRMs were certified by calibrated mass spectrometry with a collision cell multi‐collector ICP‐MS. The mass discrimination effect of the instrument was corrected with corresponding 78Se/76Se isotope mixtures and 82Se/76Se isotope mixtures, which were gravimetrically prepared with purified, isotopically enriched selenium materials. Homogeneity and stability tests were performed, and no significant influences were found. The uncertainty of the property values of the iCRMs was evaluated according to the Guide to the Expression of Uncertainty in Measurement (GUM) of ISO/BIPM and ISO Guide 35. The δ82/76Se value of GBW 04457 relative to NIST SRM 3149 was also calculated. These iCRMs are intended for use in calibration of instruments and evaluation of methods for the determination of selenium isotope ratios.  相似文献   
8.
In this article, we document a detailed analytical characterisation of zircon M127, a homogeneous 12.7 carat gemstone from Ratnapura, Sri Lanka. Zircon M127 has TIMS‐determined mean U–Pb radiogenic isotopic ratios of 0.084743 ± 0.000027 for 206Pb/238U and 0.67676 ± 0.00023 for 207Pb/235U (weighted means, 2s uncertainties). Its 206Pb/238U age of 524.36 ± 0.16 Ma (95% confidence uncertainty) is concordant within the uncertainties of decay constants. The δ18O value (determined by laser fluorination) is 8.26 ± 0.06‰ VSMOW (2s), and the mean 176Hf/177Hf ratio (determined by solution ICP‐MS) is 0.282396 ± 0.000004 (2s). The SIMS‐determined δ7Li value is ?0.6 ± 0.9‰ (2s), with a mean mass fraction of 1.0 ± 0.1 μg g?1 Li (2s). Zircon M127 contains ~ 923 μg g?1 U. The moderate degree of radiation damage corresponds well with the time‐integrated self‐irradiation dose of 1.82 × 1018 alpha events per gram. This observation, and the (U–Th)/He age of 426 ± 7 Ma (2s), which is typical of unheated Sri Lankan zircon, enable us to exclude any thermal treatment. Zircon M127 is proposed as a reference material for the determination of zircon U–Pb ages by means of SIMS in combination with hafnium and stable isotope (oxygen and potentially also lithium) determination.  相似文献   
9.
Election probe microanalysis of indicator minerals is extensively used in the exploration for kimberlite deposits, the evaluation of specific kimberlite occurrences for their diamond bearing potential and to classify grains into different chemical and lithological mantle associations. Kimberlite exploration programmes can involve several tens of thousands of indicator mineral analyses. Procedures for monitoring data quality and consistency of analyses across large data sets are commonly absent. Suitable monitor minerals should be used to verify the data quality of kimberlite exploration and evaluation data sets. This material should have a suitable composition, be homogenous, be available in sufficient quantities and have a similar appearance to the unknown samples. Garnet P1, a megacryst garnet from the Premier kimberlite, was found to have a suitable composition as a monitor for kimberlite garnet analyses. Data were collected on the monitor material at regular intervals during routine analyses, over an extended period, both as a fixed grain mounted on the sample holder and as separate grains set within batches of routine samples. The data were evaluated to assess the quality and consistency in the analyses of large data sets over time. The monitor material was also analysed at independent laboratories using their routine analytical set-up and calibration procedures for comparative purposes. Values are given for the mean ± 2s range, which can serve as guide values for acceptable analyses for all elements.  相似文献   
10.
A thermal ionisation mass spectrometric technique enabled the abundance of Zn in geological and biological reference materials and water samples to be measured by double spiking isotope dilution mass spectrometry enriched in the 67Zn and 70Zn isotopes. In the past, thermal ionisation mass spectrometry proved to be difficult for low-level zinc isotopic measurements. The size of Zn samples used for isotopic determination, in particular the biological RMs, represents an important breakthrough. These results represent the most accurate and precise concentrations measured for Zn in these samples. The maximum fractional uncertainty was that for TILL-3 (2%), while the minimum fractional uncertainty was 0.7% for both BCR-1 and W-2. The inhomogeneity of Zn in HISS-1 was revealed while other reference materials appeared homogeneous at the 95% confidence uncertainty. The certified concentration of Zn in HISS-1 and IMEP-19 by their producers are 28% and 3.8% higher than the values measured in this work. These are the first Zn concentration measurements in these materials by the isotope dilution-TIMS technique, except for BCR-1, NIES No 9 and IMEP-19. Reducing the blank enabled accurate measurement in water at the ng g-1 level demonstrating the applicability of the technique for low-level Zn samples.  相似文献   
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号